The Stainless Steel Tablet Press adopts an automatic rotary structure. This design allows the tableting process to proceed continuously, greatly improving production efficiency. The punch of the lower punch extends from the lower end of the middle die hole into the middle die hole to seal the bottom of the middle die hole. The feeder is used to fill the middle die hole with materials. The punch of the upper punch falls into the middle die hole from the upper end of the middle die hole and moves downward for a certain distance to press the powder into tablets. The upper punch lifts out of the hole, and the lower punch rises to push the tablet out of the middle die hole, completing a tableting process.
1. The whole machine is made of stainless steel, which has good corrosion resistance and wear resistance, and can ensure the service life of the equipment and the hygiene requirements of drug production. Stainless steel is also easy to clean and maintain, and meets the GMP standards of the pharmaceutical industry.
2. Rotary Tablet Press Machine adopts an automatic rotary structure, which reduces the time and labor intensity of manual operation, and can complete the tableting production task quickly and efficiently.
3. The rotary speed of the zp9 rotary tablet press is usually 30 rpm, which is moderate, which can not only ensure production efficiency, but also ensure the stability and accuracy of the tableting process
4. The motor power of the rotary punch tablet press is 2.2kW, the energy consumption is relatively low, and the operating cost is relatively economical.
5. The overall size is 480*490*1100mm, the overall structure of the equipment is relatively compact, and the space occupied is small, which is convenient for layout and installation in the production workshop.
Preparation work before operation of ZP-9B stainless steel automatic rotary tablet press:
Inspect the equipment:
1.Check whether the rotary tablet press is clean and confirm that it is within the effective period of cleaning. Check whether there is dust, stains, residual drugs, etc. on the surface of the equipment, and clean it if necessary.
2.Check the lubricating oil level in the reduction box to ensure that the lubricating oil is sufficient to ensure the normal operation of the equipment. At the same time, check the integrity of the equipment and check whether the components are damaged or loose, such as whether the die, feeder, hopper, etc. are firmly installed.
3.Check the tightness of all the connecting parts of the machine before the trial run, including screws, nuts and other connecting parts, to ensure that the equipment will not loosen during operation.
Prepare materials and molds:
1.Prepare the required materials according to production needs. The materials should be dry and fluid granular raw materials and meet the quality requirements of medicines or other products.
2.Select a suitable die and check whether the specifications of the die are correct and whether there is wear, deformation, etc. Ensure that the die matches the equipment and can be installed and used normally.
Prepare a receiving container:
Place a receiving container near the discharge port of the equipment to receive the compressed tablets.
The Stainless Steel Tablet Press adopts an automatic rotary structure. This design allows the tableting process to proceed continuously, greatly improving production efficiency. The punch of the lower punch extends from the lower end of the middle die hole into the middle die hole to seal the bottom of the middle die hole. The feeder is used to fill the middle die hole with materials. The punch of the upper punch falls into the middle die hole from the upper end of the middle die hole and moves downward for a certain distance to press the powder into tablets. The upper punch lifts out of the hole, and the lower punch rises to push the tablet out of the middle die hole, completing a tableting process.
1. The whole machine is made of stainless steel, which has good corrosion resistance and wear resistance, and can ensure the service life of the equipment and the hygiene requirements of drug production. Stainless steel is also easy to clean and maintain, and meets the GMP standards of the pharmaceutical industry.
2. Rotary Tablet Press Machine adopts an automatic rotary structure, which reduces the time and labor intensity of manual operation, and can complete the tableting production task quickly and efficiently.
3. The rotary speed of the zp9 rotary tablet press is usually 30 rpm, which is moderate, which can not only ensure production efficiency, but also ensure the stability and accuracy of the tableting process
4. The motor power of the rotary punch tablet press is 2.2kW, the energy consumption is relatively low, and the operating cost is relatively economical.
5. The overall size is 480*490*1100mm, the overall structure of the equipment is relatively compact, and the space occupied is small, which is convenient for layout and installation in the production workshop.
Preparation work before operation of ZP-9B stainless steel automatic rotary tablet press:
Inspect the equipment:
1.Check whether the rotary tablet press is clean and confirm that it is within the effective period of cleaning. Check whether there is dust, stains, residual drugs, etc. on the surface of the equipment, and clean it if necessary.
2.Check the lubricating oil level in the reduction box to ensure that the lubricating oil is sufficient to ensure the normal operation of the equipment. At the same time, check the integrity of the equipment and check whether the components are damaged or loose, such as whether the die, feeder, hopper, etc. are firmly installed.
3.Check the tightness of all the connecting parts of the machine before the trial run, including screws, nuts and other connecting parts, to ensure that the equipment will not loosen during operation.
Prepare materials and molds:
1.Prepare the required materials according to production needs. The materials should be dry and fluid granular raw materials and meet the quality requirements of medicines or other products.
2.Select a suitable die and check whether the specifications of the die are correct and whether there is wear, deformation, etc. Ensure that the die matches the equipment and can be installed and used normally.
Prepare a receiving container:
Place a receiving container near the discharge port of the equipment to receive the compressed tablets.
Copyright © 2023 Foshan Xingle Machinery Equipment Co.,Ltd. 粤ICP备2023093194号 All rights reserved. Privacy Policy | Sitemap | Support By Leadong